      PERBEDAAN CITRA ANATOMI ORBITA AXIAL PADA CT SCAN ORBITA PADA PENGGUNAAN VARIASI SLICE THICKNESS DAN REKONSTRUKSI ALGORITMA PESAWAT MSCT HITACHI ECLOS 16 SLICE DI RSUD NGANJUK

      Date
      2017
      Author
      KARNOTO
      Metadata
      Show full item record
      Abstract
      The difference of image quality of CT Scan Orbita has been done by using variation of slice thickness and reconstruction of Algorithm in Radiology Installation with RSUD Nganjuk. The purpose of this research is to know whether there is difference of picture quality of CT Scan Orbita by using Slice thickness and Algorithm Reconstruction and to know Slice thickness and Algorithm Reconstruction which produce best picture quality.The type of this research is quantitative research with experimental approach. Data retrieval is done by performing three scanning on CT Scan Orbita examination by using the same parameter so as to generate Raw data. Then the results are reconstructed with variations of Slice thickness and different Algorithm Reconstruction that is 1 mm, 2 mm, 3 mm, 4 mm and 5 mm and Reconstruction of Smooth, Standart and Sharp Algorithm so as to get the number of variation combination as many as fifteen variations. Shooting is done in the same scanning area for each slice thickness and reconstruction algorithm. Furthermore, each of the images was evaluated by 3 (three) respondents (radiologist) using check list with total sample of forty five samples. Data were analyzed using crosstabulasi and continued with Kolmogorov-Smirnov normality test and Paired T test because the hypothesis type was comparative with more than two sample groups paired with ordinal data type.The results showed that there was a significant difference in picture quality of CT Scan Orbita with p value (
      URI
      http://repository.poltekkes-smg.ac.id//index.php?p=show_detail&id=14056
      Collections
      • Repository Politeknik Kesehatan Kemenkes Semarang [19935]

      Copyright © Badan Litbangkes - Kementerian Kesehatan RI
      Jl. Percetakan Negara no.29, Jakarta Pusat 10560, Indonesia
      All rights reserved. 2019
      Contact Us | Send Feedback
        

       

      Browse

      All of R2KNCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      LoginRegister

      Copyright © Badan Litbangkes - Kementerian Kesehatan RI
      Jl. Percetakan Negara no.29, Jakarta Pusat 10560, Indonesia
      All rights reserved. 2019
      Contact Us | Send Feedback