      ANALISA PENERAPAN FAKTOR EKSPOSI ATURAN 15 % TERHADAP KUALITAS RADIOGRAF DAN DOSIS RADIASI RADIOGRAFI PELVIS PADA PENCITRAAN DIRECT DIGITAL RADIOGRAPHY

      Date
      2017
      Author
      WENING ANDAYANI
      Metadata
      Show full item record
      Abstract
      Research on radiograph quality is image resolution resulting from standard exposure factor on direct digital radiography imaging at RSUD Moewardi Surakarta Radiology installation of 85 kVp and 20 mAs, and modification of exposure factor using 15% rule is 98 kVp 10 mAs and 72 kVp 40 MAs. This study aims to determine the radiograph quality of image resolution and radiation dose received by the detector with the exposure factor of 15% rule.The type of this research is quantitative with experimental approach done on direct digital radiography imaging in radiology installation of RSUD Moewardi Surakarta using pelvic phantom and bar tool pattern and exposure three times using exposure factor standard 85 kVp 20 mAs and modification 15% rule that is 98 kVp 10 mAs and 72 kVp 40 mAs. After that the pelvic radiograph of the pelvis AP in read by respondents with three respondents and the data in can be made graph and then in descriptive analysis. Look for the dose of radiation received by the detector by calculating the intensity.Based on the result of the reading of the bar pattern by the respondent of image resolution on the radiograph of the modified exposure factor modification factor 15% is 98 kVp 10 mAs obtained values of 1.6 and 2.13, and 72 kVp 40 mAs obtained 2.0 and 1.8. Which means Ha is rejected, so there is a 15% rule relationship to radiographic quality. At the dose of radiation received by the detector at 98 kVp 10 mAs obtained results 4.8 x 10-11 ?Gy and at 72 kVp 40 mAs obtained results 10.4 x 10-11 ?Gy.Keyword : 15% rule, pelvis, image resolution, dose of radiation, direct digital radiography
      URI
      http://repository.poltekkes-smg.ac.id//index.php?p=show_detail&id=14065
      Collections
      • Repository Politeknik Kesehatan Kemenkes Semarang [19935]

      Copyright © Badan Litbangkes - Kementerian Kesehatan RI
      Jl. Percetakan Negara no.29, Jakarta Pusat 10560, Indonesia
      All rights reserved. 2019
      Contact Us | Send Feedback
        

       

      Browse

      All of R2KNCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      LoginRegister

      Copyright © Badan Litbangkes - Kementerian Kesehatan RI
      Jl. Percetakan Negara no.29, Jakarta Pusat 10560, Indonesia
      All rights reserved. 2019
      Contact Us | Send Feedback