View Item 
      •   R2KN Home
      • Politeknik Kesehatan Kemenkes
      • Politeknik Kesehatan Kementerian Kesehatan Semarang
      • Repository Politeknik Kesehatan Kemenkes Semarang
      • View Item
      •   R2KN Home
      • Politeknik Kesehatan Kemenkes
      • Politeknik Kesehatan Kementerian Kesehatan Semarang
      • Repository Politeknik Kesehatan Kemenkes Semarang
      • View Item
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      PROSEDUR PEMERIKSAAN MRI GENU PADA KASUS TUMOR MENGGUNAKANBODY COILDI INSTALASI RADIOLOGI RUMAH SAKIT PANTI RAPIH YOGYAKARTA

      Date
      2017
      Author
      MUCHAMAD GILANG PUTRA PRADANA
      Metadata
      Show full item record
      Abstract
      PROCEDURE OF MRI GENU USE BODY COIL FOR TUMOR CASE IN RADIOLOGY INSTALLATION OG PANTI RAPIH HOSPITAL YOGYAKARTAMUCHAMAD GILANG PUTRA P1), RINI INDATI2), SITI DARYATI3)ABSTRACTMRI (Magnetic Resonance Imaging) is a medical imaging technique that uses magnetic and radiofrequency fields to visualize and analyze body tissues (muscles, ligaments, cartilage, joints), blood flow, and metabolic functions of the body. In the application of magnetic field used magnitude 0.064 Tesla - 1.5 Tesla (Notosiswoyo, 2004). On the genuine MRI examination by Moeller and Reif using coils knee or genu coil but in Installation Radiology Panti Rapih Yogyakarta using a special body coil on the case of a broad tumor.The type of this research is qualitative research with case study approach. The data were collected by observation, documentation, interview to radiologist and sending doctor from March to June 2017. Data obtained in the analysis using open categorization and coding tableThe purpose of this research is to know the procedure of MRI Genu examination on tumor case using body coil, the reason of body coil use, and know the profitability and loss The result from the research shows that the use of body coil in the case of tumor in Radiology Installation Panti Rapih Yogyakarta Hospital is not done special preparation on Patients only peripheral different tools, because that is prepared is a body coil. The MRI Genu examination technique in tumor cases using this body coil is the same as the MRI genu-inspection technique in general, it just does not use a saggital cut to show the ACL. The use of body coil is performed to show a wider organ than a special coil genu but the image results from the use of body coil decreased the quality of resolution so to see the detail will be difficult, but the results of this image can already make the diagnosisKata kunci :MRI Genu, body coil, kasus tumor dan body coil1)Semarang Student of Diploma IV Radiodiagnostic and Radioteraphy of Semarang2)3)Lecture of Departement Radiodiagnostic and Radioteraphi of Politeknik Kesehatan Kementrian Kesehatan Semarang
      URI
      http://repository.poltekkes-smg.ac.id//index.php?p=show_detail&id=14210
      Collections
      • Repository Politeknik Kesehatan Kemenkes Semarang [19935]

      Copyright © Badan Litbangkes - Kementerian Kesehatan RI
      Jl. Percetakan Negara no.29, Jakarta Pusat 10560, Indonesia
      All rights reserved. 2019
      Contact Us | Send Feedback
        

       

      Browse

      All of R2KNCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      LoginRegister

      Copyright © Badan Litbangkes - Kementerian Kesehatan RI
      Jl. Percetakan Negara no.29, Jakarta Pusat 10560, Indonesia
      All rights reserved. 2019
      Contact Us | Send Feedback