View Item 
      •   R2KN Home
      • Politeknik Kesehatan Kemenkes
      • Politeknik Kesehatan Kementerian Kesehatan Semarang
      • Repository Politeknik Kesehatan Kemenkes Semarang
      • View Item
      •   R2KN Home
      • Politeknik Kesehatan Kemenkes
      • Politeknik Kesehatan Kementerian Kesehatan Semarang
      • Repository Politeknik Kesehatan Kemenkes Semarang
      • View Item
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      PENGARUH VARIASI MULTIVANE PERCENTAGE TERHADAP KUALITAS CITRA DAN INFORMASI ANATOMI PADA CITRA MRCP SEKUEN T2 TSE POTONGAN AXIAL

      Date
      2018
      Author
      Viky Putra Pamungkas
      Metadata
      Show full item record
      Abstract
      MRCP examination involving abdominal organs often cause motion artifacts caused by irregular breathing of patients, there is a method of image repair to reduce the motion of these artifacts by using Multivane technique. Multivane itself is influenced by several factors such as Multivane Percentage, if Multivane Percentage is set low it will produce low SNR and if set too high it will produce high SNR and image will blur. The purpose of this study was to determine the effect of Multivane Percentage variation on image quality and anatomical information.This research is a quantitative method. Reasearch subject is Radiologist specialist as research respondent. Research samples using 8 person who become the research probandus. The acquisition is do five times with variation of Multivane Percentage 80%, 100%, 160%, 240%, 320%.. Another parameter which controlled is TR 4000 ms, TE 100 ms, FOV 360 mm, Slice Thickness 7mm. Aspects of image quality Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR) and Information Anatomy in this study is in the organ area of Gallbladder, Cystic duct, Common Bile duct, Left Hepatic duct, Right Hepatic. Process and data analysis is done by influence test on image quality anda anatomy information.The result of the analysis of the effect of Multivane Percentage variation on SNR and CNR image quality showed significant influence with significane value 0.001 (p
      URI
      http://repository.poltekkes-smg.ac.id//index.php?p=show_detail&id=15565
      Collections
      • Repository Politeknik Kesehatan Kemenkes Semarang [19935]

      Copyright © Badan Litbangkes - Kementerian Kesehatan RI
      Jl. Percetakan Negara no.29, Jakarta Pusat 10560, Indonesia
      All rights reserved. 2019
      Contact Us | Send Feedback
        

       

      Browse

      All of R2KNCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      LoginRegister

      Copyright © Badan Litbangkes - Kementerian Kesehatan RI
      Jl. Percetakan Negara no.29, Jakarta Pusat 10560, Indonesia
      All rights reserved. 2019
      Contact Us | Send Feedback