Show simple item record

dc.contributoren-US
dc.creatorAndiarsa, Dicky
dc.creatorSetianingsih, Ika
dc.creatorFadilly, Abdullah
dc.creatorHidayat, Syarif
dc.creatorSetyaningtyas, Dian Eka
dc.creatorTriyuana, Windy
dc.date2017-03-18
dc.date.accessioned2019-12-17T10:50:03Z
dc.date.available2019-12-17T10:50:03Z
dc.identifierhttp://ejournal.litbang.depkes.go.id/index.php/sel/article/view/6379
dc.identifier10.22435/sel.v3i1.6379.24-30
dc.identifier.urihttp://r2kn.litbang.kemkes.go.id:8080/handle/123456789/83944
dc.descriptionABSTRAK Pemanfaatan air minum isi ulang untuk memenuhi kebutuhan rumah tangga yang semakin meningkat, menyebabkan semakin banyaknya ditemui depo air minum isi ulang yang ada di Kecamatan Batulicin, Kabupaten Tanah Bumbu. Tujuan dari penelitian ini adalah melakukan evaluasi cara pengambilan air pada depo air minum isi ulang dengan dan tanpa desinfeksi alkohol pada lubang tempat keluarnya air isi ulang berdasarkan pemeriksaan bakteriologis air di Kecamatan Tanah Bumbu, Kabupaten Batulicin. Pengumpulan sampel dilakukan pada bulan Juni 2015. Sebanyak 5 sampel air dari depo air isi ulang yang berbeda berhasil diperoleh. Pengambilan sampel pada 3 depo di desa Gunung Tinggi dilakukan dengan menggunakan desinfeksi alkohol pada lubang keluarnya air, sedangkan pada 2 depo lainnya di desa Kersik Putih tidak menggunakan desinfeksi alkohol pada lubang keluarnya air. Pemeriksaan mikrobiologis air yang dilakukan meliputi MPN, TPC, media selektif, pewarnaan gram dan biokimia. Berdasarkan hasil pemeriksaan dan uji statistik dengan menggunakan Uji Mann-Whitney diketahui bahwa tidak ada perbedaan yang signifikan dari dua cara pengambilan air minum isi ulang (P=0,39) dan Escherichia coli ditemukan pada sampel milik depo D dan E. ABSTRACT Increased utilization of refill drinking water to meet the household needs were adjacent with the number of refill drinking water depot in Batulicin, Tanah Bumbu District. The aim of this study was to evaluate the method of water discharge in the refill drinking water depot either with or without alcohol disinfection in the refill water discharging-hole by bacteriological examination. This research was observational study design. Sample collection was conducted in June 2015. Water samples from different water depot were successfully obtained. Sampling at three depots in Gunung Tinggi Village performed using alcohol to disinfect the water discharging-hole, on a contrary two depots in Kersik Putih Village was performed without alcohol disinfection. Microbiological examination conducted were MPN, TPC, Selective media, gram staining and biochemical test. Based on the microbiological examination and statistical analysis using the Mann-Whitney test, we found that there was no significant difference of bothrefill water discharging method (p=0.39) and Escherichia coli found in the sample belonged to depot D and E.en-US
dc.formatapplication/pdf
dc.languageen
dc.publisherBalai Penelitian dan Pengembangan KesehatanAcehen-US
dc.sourceSel Jurnal Penelitian Kesehatan; Vol 3, No 1 (2016): SEL; 24-30en-US
dc.subjectbacteriological examination, the refill drinking water depot, method evaluationen-US
dc.titleUJI TERHADAP CARA PENYEDIAAN AIR ISI ULANG PADA DEPO ISI ULANG DI KECAMATAN BATULICIN KABUPATEN TANAH BUMBUen-US
dc.typePeer-reviewed Articleen-US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record